Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Vapour Pressure was determined according to EU Method A.4 (Vapour Pressure).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
147.5 Pa
Remarks on result:
other: (means of 2 runs)
Transition / decomposition
Transition / decomposition:
no

Applicant's summary and conclusion

Conclusions:
The following vapour pressure (A4) result was obtained: 147.5 Pa @ 20°C (mean of 2 runs).