Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 15th to February 28th 2011
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
equilibrium method closed cup

Test material

Constituent 1
Reference substance name:
Epoxy Resin T1600
EC Number:
937-130-0
IUPAC Name:
Epoxy Resin T1600

Results and discussion

Any other information on results incl. tables

No flash point was observed up to 150.0°C (corrected value).

Applicant's summary and conclusion