Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8 December 2009 - 17 December 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. certificate)
Key result
Auto-ignition temperature:
> 400 °C
Atm. press.:
ca. 1 008 mBar
Conclusions:
MMB-Ac was determined not to auto-ignite below 400°C.

Description of key information

MMB-Ac was determined not to auto-ignite below 400°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information