Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 December 2010 – 21 January 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to an UN guideline and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.4: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods…, Test N.4: “Test Method for Self-heating Substances”, 2003.
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
14,14',15,15'-tetradehydro-7,7'-spirobi[dibenzo[b,g][1,9,4,6]dioxadiazacyclododecine]
EC Number:
700-609-8
Cas Number:
1231148-36-9
Molecular formula:
C31H24N4O4
IUPAC Name:
14,14',15,15'-tetradehydro-7,7'-spirobi[dibenzo[b,g][1,9,4,6]dioxadiazacyclododecine]
Details on test material:
- Name of test material (as cited in study report): SX-1
- Molecular formula: C31H24N4O4
- Molecular weight: 516.55
- Substance type: Pale yellow powder
- Physical state: solid
- Analytical purity: 99.7%
- Lot/batch No.: 008809
- Expiration date of the lot/batch: 02 November 2012
- Stability under test conditions: Stable
- Storage condition of test material: At room temperature in the dark


Results and discussion

Auto-ignition temperature (liquids / gases)
Remarks on result:
other: no exothermic effects were observed during the test period at elevated temperature, therefore SX-1 is not a self-heating substance
Relative self-ignition temperature (solids)
Remarks on result:
other: no exothermic effects were observed during the test period at elevated temperature, therefore SX-1 is not a self-heating substance

Any other information on results incl. tables

No exothermic effect of the test substance was observed. It demonstrated that the test substance is “not a self-heating substance”. According to the guideline, no further testing was required. After the experiment, the consistency of the sample was unchanged, i.e. no reaction and/or decomposition was observed.

Applicant's summary and conclusion

Conclusions: