Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15th January 2010 to 23rd February 2010.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
Date of GLP inspection: 15/09/09 Date of Signature on GLP certificate: 26/11/09
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsor's identification : DVS005u (aka Weston 705)
Description : clear colourless viscous liquid
Batch number : MW9F23A901
Date received : 05 November 2009
Expiry date : 15 June 2010
Storage conditions : approximately 4°C, under nitrogen, in the dark

Results and discussion

Flash point
Flash point:
228 °C
Atm. press.:
101.325 kPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test material has been determined to be 228 ± 2°C.
Executive summary:
Method: The flash point was determined using a closed cup equilibrium method, Method A9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008. Results: The flash point of the test material has been determined to be 228 ± 2°C.