Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Not flammable

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Flammability

The flammability of ITC 288/S has been determined according the EU method A.10 of the Commission directive 84/449/EEC and the GLP.

In the preliminary test, the test material was made into a pile 250 mm x 20 mm x 10 mm and attempts were made to ignite the pile at one end using an air-rich bunsen burner flame. This was performed six times. In the six tests performed, the pile failed to support combustion.

Additionnaly, the moisture content was determined to be 13.4%.

Flammability in contatct with water and pyrophoricity

These end-points are waived based on the absence of structural chemical alerts.