Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 Jun - 26 Oct 1999
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Atm. press.:
ca. 1 013 hPa
Decomposition:
yes
Decomp. temp.:
ca. 165 °C
Remarks on result:
other: the decomposition is autocatalysed for pure and technical product

Preliminary tests showed significant exothermic process. The decomposition corresponding to an exothermic process began at about 165 °C for pure grade and the technical grade. The both exothermic processes were found to be auto-catalytic.

 

Analytical grade

Technical grade

Decomposition temperature /°C

164.5

165.1

There are no values given for pressure but assumed to be measured at normal pressure (1013 hPa).

Description of key information

decomposition temperature: ca. 165 °C at ca. 1013 hPa

Key value for chemical safety assessment

Additional information

The boiling point for the test item could not be determined due to decomposition at ca. 165 °C. The decomposition is autocatalysed for pure and technical product. Differential scanning calorimetry according to OECD Guideline 103 was used.