Registration Dossier

Ecotoxicological information

Endpoint summary

Administrative data

Description of key information

Additional information

TERRESTRIAL TOXICITY

As the registration substance has a low sorption potential to sewage sludge (see IUCLID Chapter 5.4.1) transfer to the terrestrial compartment via amendment of sewage sludge to agricultural soil is very limited. In addition the registration substance is rapidly degraded in the terrestrial compartment (see IUCLID Chapter 5.2.3). Based on these facts it can be concluded that soil is not the target compartment and therefore terrestrial ecotoxicity tests are not warranted. Due to the low sorption properties the PNEC soil can be calculated from the PNEC freshwater using the equilibrium parititioning method (see REACH Guidance R.10.6.1).