Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 911-490-9 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- November 27th, 2012 - April 7th, 2013
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- (2008)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- (2001)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- HPLC estimation method
- Media:
- soil
- Radiolabelling:
- no
- Details on study design: HPLC method:
- CALCULATION OF pKa:
The following pKa values in the pH range of 1 - 14 were calculated using the Perrin calculation method (pKalc 5.0, module in Pallas 3.0, CompuDrug International San Francisco, USA):
2,2’-[(4-methylphenyl)imino]-diethanol: acidic (none); basic: RARN(R1R2): pKa 4.02
2-{[2-(2-hydroxyethoxy)ethyl](4-methylphenyl)amino}ethanol: acidic (none); basic: RARN(R1R2): pKa 3.94
HPLC METHOD CONDITIONS:
Instrument: Acquity UPLC system (Waters, Milford, MA, USA)
Detector: Acquity UPLC TUV detector (Waters)
Column: Acquity UPLC HSS, 50 mm x 2.1 mm i.d., dp = 1.8 µm (Waters)
Column temperature: 35°C ± 1°C
Mobile phase: 30/70 (v/v) methanol/water
Flow : 0.4 mL/min
Injection volume: 5 μL
UV detection: 210 nm
REFERENCE SUBSTANCES: acetanilide; Monuron; 2,5-dichloroaniline; benzoic acid phenylester and Fenthion
Unretained compound: Formamide
PREPARATION OF SOLUTIONS:
Solution of the unretained compound
A 5.22 g/L stock solution of formamide in methanol was used. The stock solution was diluted to obtain an end solution of 30/70 (v/v) methanol/water. The formamide blank solution was 30/70 (v/v) methanol/water.
Reference substance solutions
Stock solutions of the reference substances at concentrations of approximately 1 g/L in methanol were used. The stock solutions were diluted to obtain an end solution of 30/70 (v/v) methanol/water. The blank solution for the reference substance solutions was 30/70 (v/v) methanol/water.
Test solution
A 2180 mg/L stock solution of the test substance was prepared in methanol. The stock solution was diluted to obtain an end solution of 30/70 (v/v) methanol/water. The final concentration of the test substance solution was 9.98 mg/L. The test substance blank solution was 30/70 (v/v) methanol/water.
The reference substance and test substance solutions were injected in duplicate. Blank solutions were analysed by single injection.
PERFORMANCE OF THE STUDY
Solutions of reference substances with known log Koc values based on soil adsorption data and the test substance were analysed. The capacity factor (k') of each compound was calculated from its retention time. The log k’ values of the references substances were plotted against the known log Koc values. A linear regression program was used to calculate the calibration curve. Linear regression analysis was performed using the least squares method. The coefficient of correlation (r) was calculated. The log Koc value for the test substance was calculated by substituting its mean log k’ in the calibration curve: log k’ = 0.709 x log Koc – 0.978 (r = 0.94, n = 12). The value of log Koc obtained from duplicate measurements was within ± 0.25 log units. - Analytical monitoring:
- yes
- Type:
- log Koc
- Value:
- 2.22 dimensionless
- Temp.:
- 35 °C
- Remarks on result:
- other: Peak area 52%
- Type:
- log Koc
- Value:
- 2.44 dimensionless
- Temp.:
- 35 °C
- Remarks on result:
- other: Peak area 38%
- Type:
- log Koc
- Value:
- 2.51 dimensionless
- Temp.:
- 35 °C
- Remarks on result:
- other: Peak area 4.9%
- Type:
- log Koc
- Value:
- 2.67 dimensionless
- Temp.:
- 35 °C
- Remarks on result:
- other: Peak area 2.4%
- Key result
- Type:
- log Koc
- Value:
- 2.33 dimensionless
- Temp.:
- 20 °C
- Remarks on result:
- other: weight-averaged value based on four main components covering 97.3% (by area-%) of the whole substance (Koc = 214)
- Details on results (HPLC method):
- In the HPLC chromatogram of the test substance, a total number of 18 peaks have been identified from which four peaks with retention times of 3.47 min. (52% peak area), 4.65 min. (38% peak area), 5.17 min. (4.9% peak area) and 6.46 min. (2.4% peak area) were observed. Under the same conditions, the retention time of benzoic acid phenylester (log Koc 2.87) was 10.55 - 10.53 minutes.
- Transformation products:
- not measured
- Validity criteria fulfilled:
- yes
- Conclusions:
- The HPLC method (in accordance with EC C.19 and OECD 121 and in compliance with GLP) was performed to determine the adsorption coefficient (soil) of the test substance. The HPLC chromatogram of the test solution showed four major peaks (with peak areas of 52%, 38%, 4.9% and 2.4%). The log Koc for the major peaks were 2.22, 2.44, 2.51 and 2.67, respectively. The weight-averaged logKoc value considering the four main components has been derived to be 2.33 (= log 214). HPLC column temperature: 35°C ± 1°C, but the log Koc of reference substances have been determined at 20 °C, thus the 2.33 value is determined as well for 20 °C.
Reference
Table: Measurements and results for the Koc determination:
Substance |
mean tr |
log Koc |
Koc |
Area |
|
|
|
|
|
Formamide (t0) |
0.703 |
|
|
|
|
|
|
|
|
Acetanilide |
|
1.26 |
|
|
Monuron |
|
1.99 |
|
|
2,5-Dichloroaniline |
|
2.55 |
|
|
Naphthalene |
|
2.75 |
|
|
Benzoic acid phenylester |
|
2.87 |
|
|
Fenthion |
|
3.31 |
|
|
|
|
|
|
|
peak 1 |
1.316 |
1.30 |
2.0´101 |
0.032 |
peak 2 |
1.571 |
1.51 |
3.2´101 |
0.30 |
peak 3 |
1.836 |
1.67 |
4.7´101 |
0.85 |
peak 4 |
2.237 |
1.86 |
7.2´101 |
0.44 |
peak 5 |
2.366 |
1.91 |
8.1´101 |
0.060 |
peak 6 |
2.614 |
1.99 |
9.8´101 |
0.012 |
peak 7 |
2.781 |
2.04 |
1.1´102 |
0.021 |
peak 8 |
3.285 |
2.18 |
1.5´102 |
0.0054 |
peak 9 |
3.469 |
2.22 |
1.7´102 |
52 |
peak 10 |
4.647 |
2.44 |
2.7´102 |
38 |
peak 11 |
5.174 |
2.51 |
3.2´102 |
4.9 |
peak 12 |
6.035 |
2.62 |
4.2´102 |
0.058 |
peak 13 |
6.271 |
2.65 |
4.4´102 |
0.046 |
peak 14 |
6.464 |
2.67 |
4.6´102 |
2.4 |
peak 15 |
7.104 |
2.73 |
5.4´102 |
0.36 |
peak 16 |
9.456 |
2.92 |
8.4´102 |
0.024 |
peak 17 |
9.583 |
2.93 |
8.6´102 |
0.084 |
peak 18 |
9.926 |
2.96 |
9.0´102 |
0.058 |
|
|
|
|
|
Description of key information
The weight-averaged logKoc value considering the four main components has been derived to be 2.33 (= log 214).
Key value for chemical safety assessment
- Koc at 20 °C:
- 214
Additional information
The HPLC method (in accordance with EC C.19 and OECD 121 and in compliance with GLP) was performed to determine the adsorption coefficient (soil) of the test substance. The HPLC chromatogram of the test solution showed four major peaks (with peak areas of 52%, 38%, 4.9% and 2.4%). The log Koc for the major peaks were 2.22, 2.44, 2.51 and 2.67, respectively.
The weight-averaged logKoc value considering the four main components has been derived to be 2.33 (= log 214). HPLC column temperature: 35°C ± 1°C, while it is considered that the Koc values of the reference substances, as reported in the OECD 121, have been determined at 20 °C.
[LogKoc: 2.33]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.