Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2009
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Decomposition temperature was determined by DSC, apparatus Mettler Toledo, DSC 821e, 25 - 450 °C, 3K/min, sealed glass vial in air
GLP compliance:
not specified

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

For thermal stability study

Operating temperature
Operating temp.:
> 25 - < 450 °C
Remarks on result:
other: decomposition starts at 304 °C
Sublimation:
no
Transformation products:
not measured

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Applicant's summary and conclusion

Executive summary:

The decomposition temperature of the test item was determined by DSC starting at 304°C