Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2011-04-04 to 2011-06-10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
31 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Version / remarks:
August 1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: UN Manual Test Methods 32.4; Rev. 5, 2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Batch no.: 10191-AKm
- Purity. 100.5 % (aldimine titration)
- Expiry date: 2013-06-16
Key result
Flash point:
148.5 °C
Atm. press.:
1 013 hPa

The results of the determinations are presented in the following table:

 

Program

Flash point
in °C

Notes

Pre Test

SEl

150.5

not used for calculation

Measurement 1

ENI

147.5

used for calculation

Measurement 2

ENl

150.5

not used for calculation

Measurement 3

ENl

149.5

used for calculation

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Sika Hardener MH was determined to be 148.5 °C.
Executive summary:

The determination of the flash point of Sika Hardener MH was performed according to EU Method A.9, OPPTS 830.6315 and UN Manual Test Methods 32.4. Three independent determinations were performed. The maximum variation was 3 K. Therefore, the lowest two values (which showed a variation of 2 K) were used for calculation of the mean. The flash point of Sika Hardener MH was determined to be148.5 °C.

Description of key information

The flash point of Sika Hardener MH was determined to be 148.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
148.5 °C

Additional information

The determination of the flash point of Sika Hardener MH was performed according to EU Method A.9, OPPTS 830.6315 and UN Manual Test Methods 32.4. Three independent determinations were performed. The maximum variation was 3 K. Therefore, the lowest two values (which showed a variation of 2 K) were used for calculation of the mean. The flash point of Sika Hardener MH was determined to be 148.5 °C.