Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ONU N4
Version / remarks:
[ST/SG/AC.10/11/Rev.4]
Deviations:
no
GLP compliance:
yes
Relative self-ignition temperature:
>= 239 °C
Remarks on result:
other:
Remarks:
100mm cube, at 140°C
Relative self-ignition temperature:
>= 178 °C
Remarks on result:
other:
Remarks:
25mm cube, at 140°C
Relative self-ignition temperature:
>= 213 °C
Remarks on result:
other:
Remarks:
100mm cube, at 120°C
Relative self-ignition temperature:
>= 197 °C
Remarks on result:
other:
Remarks:
100mm cube, at 100°C

According transport classification, the product has to be classified as UN3088 4.2 GE III. So for CLP, it should be classified as Self Heating Cat.2, H252.

Report extract (key results) :

Porte échantillon

Température de consigne

Conclusion

100mm

140°C

positif

25mm

140°C

négatif

100mm

120°C

positif

100mm

100°C

positif

The product is classified as cat. 2 because :

- positive result for 100mm, 140°C and

- negative result for 25mm, 140°C and

- positive result for 100mm, 100°C

Conclusions:
According transport classification, the product has to be classified as UN3088 4.2 GE III. So for CLP, it should be classified as Self Heating Cat.2, H252.
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-08-29 to 2006-09-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
, 1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
signed, 2006-12-20
Relative self-ignition temperature:
>= 340 - <= 359 °C
Remarks on result:
other:
Remarks:
at atm. press. of ca.1013.0 mBar

An exothermic reaction was observed during the test for three assays, the duration of exothermic reaction varied between 55 an 58 min. A self ignition reaction was observed during the test for two out of three assays. The maximum temperature reached by the test item was situated between 546 and 606°C.

In the study no atmospheric pressure was stated at which the self-ignition temperature was measured. Because of this it was assumed that the self-ignition temperature was measured at ca. 1013 mBar.

Conclusions:
The self-ignition temperature of the test item was situated between 340 and 359°C (corrected value).

Description of key information

The self-ignition temperature of resin acids and rosin acids, cobalt salts was situated between 340 and 359°C (corrected value).

Self heating proprieties were evaluating by test done according guideline ONU N4.

The product should be classified as self heating cat2, H252.

Key value for chemical safety assessment

Additional information