Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study was selected as the key study because the information provided for the hazard endpoint is sufficient for the purpose of classification and labeling and/or risk assessment.
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
Remarks:
The study was conducted according to the test guidelines in effect at the time of study conduct.
GLP compliance:
yes
Type of method:
gas saturation method
Temp.:
25 °C
Vapour pressure:
0.354 Pa
Remarks on result:
other: 10 mL/min flow rate
Temp.:
25 °C
Vapour pressure:
0.408 Pa
Remarks on result:
other: 8 mL/min flow rate
Conclusions:
This study and the conclusions which are drawn from it fulfill the quality criteria (validity, reliability, repeatability).
The vapour pressure was determined to be 0.354 ± 0.010 Pa at the 10 mL/min flow rate.
The vapour pressure was determined to be 0.408 ± 0.014 Pa at the 8 mL/min flow rate.
Executive summary:

A Vapour Pressure Determination (Gas Saturation Method: U.S. EPA Product Properties Test Guidelines OPPTS 830.7950) was conducted in triplicate using vapour saturator columns containing test substance treated sand. The test was done with 10 mL/min and 8 mL/min flow rates of nitrogen gas to flush the vapours from the colums into traps. The traps were then extracted, the contents analyzed by HPLC and the vapour pressure calculated.

The vapour pressure was determined to be 0.354 ± 0.010 Pa at the 10 mL/min flow rate and 0.408 ± 0.014 Pa at the 8 mL/min flow rate.

Description of key information

0.354 ± 0.010 Pa at the 10 mL/min flow rate; 0.408 ± 0.014 Pa at the 8 mL/min flow rate

Key value for chemical safety assessment

Vapour pressure:
0.354 Pa
at the temperature of:
25 °C

Additional information

EPA OPPTS 830.7950, gas saturation method