Administrative data

First-aid measures

General information:

Remove contaminated, soaked clothing immediately and dispose of safely. Adhere to personal protective measures when giving first aid. Clean body thoroughly (bath, shower). In any case show the physician the Safety Data Sheet.

After inhalation:

Ensure supply of fresh air. Remove affected person from danger area. Seek medical advice immediately.

After skin contact:

Wash off immediately with soap and water. Seek medical advice immediately.

After eye contact:

Separate eyelids, wash the eyes thoroughly with water (15 min.). Seek medical advice immediately.

After ingestion:

Call in a physician immediately and show him the Safety Data Sheet. Rinse out mouth and give plenty of water to drink. Do not induce vomiting - aspiration hazard.

Adhere to personal protective measures when giving first aid

First aider: Pay attention to self-protection!

Most important symptoms and effects, both acute and delayed:

Until now no symptoms known so far.

Indication of any immediate medical attention and special treatment needed:

Hints for the physician / hazards

In the case of swallowing with subsequent vomiting, aspiration of the lungs can occur which can lead to chemical pneumonia or asphyxiation.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media:

Dry powder, Foam, Carbon dioxide, Dry chemical extinguisher, Water spray jet.

Non suitable extinguishing media:

Full water jet

Special hazards arising from the substance or mixture:

In case of combustion evolution of dangerous gases possible. In the event of fire the following can be released: Carbon monoxide (CO); Carbon dioxide (CO2)

Advice for firefighters

Special protective equipment for fire-fighting:

Do not inhale explosion and/or combustion gases. In case of combustion use a suitable breathing apparatus. Wear full protective suit.

Other information:

Collect contaminated fire-fighting water separately, must not be discharged into the drains. Fire residues and contaminated fire-fighting water must be disposed of in accordance with the local regulations. Cool endangered containers with water spray jet.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Keep away sources of ignition. Ensure adequate ventilation. Use breathing apparatus if exposed to vapours/dust/aerosol. Avoid contact with skin, eyes and clothing. Use personal protective clothing.

Environmental precautions:

Do not discharge into the drains/surface waters/groundwater. Do not discharge into the subsoil/soil. Retain and dispose of contaminated wash water. In case of gas escape or of entry into waterways, soil or drains, inform the responsible authorities.

Methods and material for containment and cleaning up:

Pick up mechanically. Avoid raising dust. Clean contaminated floors and objects thoroughly, observing environmental regulations. Dispose of absorbed material in accordance with the regulations.

Handling and storage

Precautions for safe handling

Advice on safe handling:

Avoid dust formation. Take precautionary measures against static discharge. If workplace limits are exceeded, a respiratory protection approved for this particular job must be worn. Keep container tightly closed. Smoking, eating and drinking shall be prohibited in application area.

Advice on protection against fire and explosion:

Keep away from sources of heat and ignition. No smoking. Take precautionary measures against static discharge.

Conditions for safe storage, including any incompatibilities

Recommended storage temperature:

Value >15 <25°C

Storage stability: Storage period up to 6 months

Requirements for storage rooms and vessels:

Keep in original packaging, tightly closed. Storage rooms must be properly ventilated. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Provide solvent-resistant and impermeable floor.

Hints on storage assembly

Do not store together with foodstuffs. Do not store with strong oxidizing agents.

Storage class according to TRGS 510 10-13

Other combustible and non-combustible substances

Further information on storage conditions

Keep container tightly closed and in a well-ventilated place. Store in a dark and dry place.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

General protective and hygiene measures

Do not smoke during work time. Hold emergency shower available. Hold eye wash fountain available. Do not inhale gases/vapours/aerosols. Avoid contact with skin and eyes. Do not eat or drink during work time. Storage of foodstuffs in work rooms is forbidden. Wash hands before breaks and after work.

Respiratory protection

Use breathing apparatus in dust-laden atmosphere. Particle filter P2

Hand protection

Chemical resistant gloves. Appropriate Material: nitrile, Material thickness 0,4mm; Breakthrough time > 480min

Eye protection

Safety glasses with side protection shield

Body protection

Clothing as usual in the chemical industry. Fire-resistant antistatic protective clothing

Stability and reactivity

Reactivity

No hazardous reactions when stored and handled according to prescribed instructions.

Chemical stability

No hazardous reactions known.

Possibility of hazardous reactions

No hazardous reactions known.

Conditions to avoid

Protect from heat and direct sunlight. Protect from light.

Decomposition temperature

Remarks:not determined

Incompatible materials

None known

Hazardous decomposition products

Toxic gases/vapours, Carbon monoxide and carbon dioxide

Disposal considerations

Waste treatment methods

Disposal recommendations for the product

Allocation of a waste code number, according to the European Waste Catalogue (EWC), should be carried out in agreement with the regional waste disposal company.

Disposal recommendations for packaging

Packaging that cannot be cleaned should be disposed off in agreement with the regional waste disposal company.