Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 Jun -30 Jul 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
GLP compliance:
no
Type of method:
other: rapid tester
Flash point:
168 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Presure corrected. Actual value: 1009 hPa.

Description of key information

168.0 °C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
168 °C

Additional information

The flash point of the substance was determined according to the EU method A.9 (closed cup).