Registration Dossier

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data is from study report
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Principles of method if other than guideline:
The Partition coefficient n-octanol/water of test chemical has been determined by the Reverse Phase High performance Liquid Chromatographic Method according to OECDS guidelines for testing of chemicals ,Method No.117
GLP compliance:
not specified
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.1
Temp.:
24
Remarks on result:
other: The value indicates that chemical is Hydrophobic in naure
Conclusions:
The Partition coefficient n-octanol/water of test chemical has been determined by the Reverse Phase High performance Liquid Chromatographic Method according to OECDS guidelines for testing of chemicals ,Method No.117 the Log kow value was determined to be 4.1.the value indicates that the test chemical is hydrophilic in nature.
Executive summary:

The Partition coefficient n-octanol/water of test chemical has been determined by the Reverse Phase High performance Liquid Chromatographic Method according to OECD guidelines for testing of chemicals, Method No.117 the Log kow value was determined to be 4.1 at 24 degree C. On the basis of this value the test chemical is considered to be hydrophilic in nature.

Description of key information

The Partition coefficient n-octanol/water of test chemical has been determined by the Reverse Phase High performance Liquid Chromatographic Method according to OECD guidelines for testing of chemicals, Method No.117 the Log kow value was determined to be 4.1 at 24 degree C.On the basis of this value the test chemical is considered to be hydrophilic in nature.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.1
at the temperature of:
24 °C

Additional information

The Partition coefficient n-octanol/water of test chemical has been determined by the Reverse Phase High performance Liquid Chromatographic Method according to OECD guidelines for testing of chemicals, Method No.117 the Log kow value was determined to be 4.1 at 24 degree C.On the basis of this value the test chemical is considered to be hydrophilic in nature.