Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Endpoint:
hydrolysis
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is highly insoluble in water
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
See the link in the 'Cross-reference' table.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 April - 21 June 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method
Water solubility:
< 0.522 µg/L
Conc. based on:
other: Yttrium
Temp.:
20 °C
pH:
>= 6.9 - <= 7
Key result
Water solubility:
< 0.663 µg/L
Conc. based on:
other: Yttrium Oxide (Y2O3)
Temp.:
20 °C
pH:
>= 6.9 - <= 7
Details on results:
Turbidity of the eluates was <0.2 NTU, thus no undissolved particles were detected in the eluates.
In all samples, a small Yttrium response was detected. This response was below the lowest calibration solution.
<0.522 µg/L yttrium was analysed at 12 and 24 ml/h flow rate with a pH of 6.9 and 7.0 respectively, with 0.5 µg/L being the lowest calibration solution. This is equivalent to < 0.663 µg/L yttrium oxide concentration.
The test substance signal in the samples from the blank column was below that of the lowest calibration standard.
Conclusions:
The substance is insoluble in water. In a study according to current OECD/EC/EPA test guidelines, the water solubility was determined using the column elution method resulting in a water solubility of <0.663 µg/L, expressed as Yttrium Oxide (Y2O3).

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion