Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well performed study according to acknowledged standard

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ISO 13320-1
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Purity: 89.7%
Expiry: 2014-06-17

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
230 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
7.1 µm
St. dev.:
0.3
Percentile:
D50
Mean:
230 µm
St. dev.:
30
Percentile:
D90
Mean:
1 003 µm
St. dev.:
224

Applicant's summary and conclusion

Conclusions:
The mass median diameter D50 of the volumetric particle size distribution is 230 µm.
Executive summary:

The volumetric particle size distribution of the substance was determined with a Malver Mastersizer apparatus with the evaluation unit Scirocco 2000. The mass median diameter was found to be 230 µm.