The Henry's Law constant was calculated by the following formula:
H (Pa*m3/mol) = (Vp x MW) / (Ws x 1000)
where:
Vp = vapour pressure = 1000 Pa (see data set, Bromos (1980))
MW = molecular weight = 180.6 g/mol
Ws = water solubility = 0.0338 g/L (see data set)

Key value for chemical safety assessment

Henry's law constant (H) (in Pa m³/mol):
5 343
at the temperature of:
20 °C

Additional information

The Henry's Law constant was determined by calculation.