Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: No deviation from A.10 guideline, GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: A.10
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
GLP Certificate as an annexe in the study report.

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 493 - < 1 980 °C
Atm. press.:
ca. 1.013 atm
Remarks on result:
other: Range is estimated from propan burner temperatures at which no auto-ignition was observed.
Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 493 - < 1 980 °C
Remarks on result:
other: Range is estimated from propan burner temperatures at which no auto-ignition was observed.
Remarks:
at atm. press. of ca.1.013 atm

Applicant's summary and conclusion

Conclusions:
APP-6505 has no auto-flammability properties at least under 500°C.