Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report Date:
2005

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Type of method:
effusion method: by loss of weight or by trapping vaporisate

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
< 0 hPa
Remarks on result:
other:
Temp.:
39.6 °C
Vapour pressure:
< 0 hPa
Remarks on result:
other:
Temp.:
50 °C
Vapour pressure:
< 0 hPa
Remarks on result:
other:

Applicant's summary and conclusion