Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air and seek medical advice.
Emergency measure - Eyes: Rinse with water for at least 15 minutes.
Emergency measure - Skin: Remove contaminated clothing and wash with plenty of soap
and water.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Carbon dioxide or dry
powder may be used for small fires. Foam may be used for
large fires.

Product arising from burning: Products arising from pyrolysis: Combustion is not complete
at temperatures below 1200 deg C. Thermal decomposition
products such as mono and dichlorobenzene, chlorobromo-
benzene, benzonitriles, dichlorobenzo-furans were found
during a pyrolysis test at 800 deg C.

Protective equipment: Protective equipment: Protective clothing and a
self-contained breathing apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Sweep up spill and place into suitable labelled containers
and dispose of by incineration or at a suitable landfill
facility. Avoid contamination of waterways and reservoirs.

Handling and storage

Handling: Ensure adequate ventilation, extract dusts from emission
source. Avoid contact with skin, eyes and clothing.

Storage: Store in a cool place away from sources of ignition, in
polyethylene- lined plastic drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: Dust explosions may occur

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: The substance can be disposed of at a suitable landfill
site. Avoid discharge into drains.

Industry - Possibility of destruction - incineration: Recommended method. The substance can be disposed of by
incineration at a suitable facility at a minimum of 1200
deg C. Waste gas treatment to remove hydrogen halides and
nitrogen oxides should be fitted.

Industry - Possibility of destruction - water purification: The substance may be removed from water purification
systems by physicochemical treatment (floculation,
filtration, absorption on carbon). Waste solids should be
disposed of by incineration. If treatment of water is not
possible incineration of contaminated water may be used.
Contaminated water should be prevented from entering the
wider aquatic environment.

Public at large - Possibility of recovery/recycling: The substance itself and preparations containing it will