Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 20, 2004 - October 29, 2004
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report Date:
2004

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
, 1992
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
signed 2004-09-06
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): PI-23513
- Substance type: technical product
- Physical state: colourless, liquid
- Storage condition of test material: ambient temperature, dark and dry

Results and discussion

Flash point
Flash point:
111 °C
Atm. press.:
1 013.3 hPa

Any other information on results incl. tables

Table 1: Preliminary measurement

Volume / ml

Start temperature / °C

Heating rate / K/min

Measured flash point / °C

4

150

2

150.0

4

100

2

114.1

4

108

2

116.0

Table 2: Results of the main test, and temperatures, where ignition (+) was detected and where not (-)

Volume / ml

Temperature / °C

Ignition + / -

Barometric pressure / hPa

Flashpoint / °C (corrected)

4

110.0

-

994.4

---

4

111.0

+

111.47

4

110.5

-

---

4

110.5

-

---

4

111.0

+

111.47

4

111.0

+

111.47

4

110.5

-

---

4

111.0

+

111.47

Applicant's summary and conclusion

Conclusions:
The flash point of the test item is 111.0 °C under atmospheric conditions (1013.3 hPa).