Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 October 2006 to 18 October 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: compliant to GLP and testing guideline; adequate coherence between data, comments and conclusions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): R0054002C, synonym IMEXINE OBH
- Physical state: beige to yellow powder
- Purity: 99.7%
- Impurities (identity and concentrations): not indicated
- Purity test date: 20 July 2006
- Lot/batch No.: R0054002C 013 L 001, synonym 0604070001
- Expiration date of the lot/batch: 01 August 2007
- Stability under test conditions: not indicated
- Storage condition of test material: in darkness, at room temperature and under nitrogen gas

Results and discussion

Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 423 °C
Remarks on result:
other:

Any other information on results incl. tables

No self ignition of the test item was observed up to 423°C.

The pressure was not indicated in the study report.

Applicant's summary and conclusion

Conclusions:
No self ignition of the test item was observed up to 423°C.