Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Move exposed person to fresh air. Symptomatic treatment.

In case of indisposition seek medical advice.
Emergency measure - Eyes: Rinse eyes with water.
Emergency measure - Skin: Wash affected skin with water.
Emergency measure - Ingestion: Symptomatic treatment. In case of indisposition, seek
medical advice.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry powder foam or water may be used.

Product arising from burning: COx, NOx, FOx, SiOx

Product determined by test: N

Protective equipment: Wear full protective clothing and self-contained breathing
apparatus.

Accidental release measures

Emergency measures in case of spillage: Wear proper protective equipment.

Sweep up spilled substance into labelled containers and
dispose of by incineration in accordance with local
regulations.

Do not wash into shower or waterway.

Handling and storage

Handling: Ensure adequate ventilation. Observe the usual precautions
for handling chemicals. Wear suitable protective gloves,
safety spectacle and mask for organic solvent.

Storage: The substance should be stored in sealed containers in well
ventilated rooms at room temperature secured from falling
down.

Packaging of the substance and or preparation: Glass containers (approximately 200 cc in size)

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Transportation must be in compliance with regional laws and
regulations
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Not known.

Chemical reaction with water: None

Dust explosion: Not to be expected

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not possible.

Industry - Possibility of neutralisation: Not possible.

Industry - Possibility of destruction: controlled discharge: Not recommended

Industry - Possibility of destruction - incineration: Incinerate with high temperatures and flue gas scrubbing.

Industry - Possibility of destruction - water purification: Not recommended

Industry - Possibility of destruction - other: Not applicable

Public at large - Possibility of recovery/recycling: Not applicable

Public at large - Possibility of neutralisation: Not applicable

Public at large - Possibility of destruction: controlled discharge: Not applicable

Public at large - Possibility of destruction - incineration: Not applicable

Public at large - Possibility of destruction - water purification: Not applicable