Registration Dossier

Administrative data

Link to relevant study record(s)

Description of key information

In the preliminary screening test in an EU Guideline A.10 study Molyvan 855 is confirmed as not highly flammable as it did not propagate combustion over the 200 mm.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

In an EU Method A.10 study conducted under GLP conditions Molyvan 855 is confirmed as not highly flammable (SafePharm Laboratories, Ltd., 1997).

Justification for classification or non-classification

Flammability: not flammable

Therefore in accordance with the classification, labelling and packaging of substances and mixtures (CLP) regulation (EC) 1272/2008, Molyvan 855 is not classified for flammability.