Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient from exposure, seek medical attention.
Emergency measure - Eyes: Rinse immediately with plenty of water and seek medical
advice.
Emergency measure - Skin: Wash with plenty of cold water, seek medical attention.
Emergency measure - Ingestion: Symptomatic treatment

Fire-fighting measures

Recommended extinguishing agent: Combustion products may contain carbon and sulphur oxides
together with some soot and hydrogen chloride gas. Use
water spray, foam, dry powder or carbon dioxide to
extinguishing fires. Wear a self-contained breathing
apparatus.

Accidental release measures

Emergency measures in case of spillage: Absorb spillage with sand, earth or other suitable
material. Transfer to waste containers for disposal by
incineration.

Handling and storage

Handling: Normal standards of good housekeeping to avoid skin and eye
contact. Avoid inhalation of high concentrations of vapour,
use in a well ventilated area. At all times wear eye/face
protection and suitable gloves. A B3 full face mask
respirator should be worn under conditions of high vapour
concentration.

Storage: Keep container tightly closed. Keep away from direct
sunlight.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: The substance rapidly hydrolyses to the sulphonic acid and
hydrochloric acid.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for reuse is not possible.

Industry - Possibility of neutralisation: Treat with copious amounts of water and neutralise with
soda ash.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method. A temperature above 950 deg C should be
used. Waste gas treatment to remove sulphur oxides and
hydrogen chloride gas is recommended.

Industry - Possibility of destruction - water purification: Not recommended, the substance is not readily
biodegradable.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.