Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18.05.-28.07.2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
3.2 other: *10-3 Pa
Temp.:
25 °C
Vapour pressure:
6.7 other: *10-3Pa
Temp.:
50 °C
Vapour pressure:
1.7 other: *10-1Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of CC-5-V at 20°C is 3.1*10-3 Pa.
Executive summary: