Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
method to determine freezing temperature

Test material

Constituent 1
Chemical structure
Reference substance name:
1,4,10,13-pentaoxacyclopentadecane
EC Number:
251-379-6
EC Name:
1,4,10,13-pentaoxacyclopentadecane
Cas Number:
33100-27-5
Molecular formula:
C10H20O5
IUPAC Name:
1,4,7,10,13-pentaoxacyclopentadecane
Specific details on test material used for the study:
Substance ID: 15-Crown-5
Lot #: 1909005
Purity: 91.8%

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
-25 °C

Applicant's summary and conclusion

Conclusions:
Freezing point: Less than -25°C
Executive summary:

The study was conducted according to OECD guideline 102, EC method A.1, and EPA/OCSPP 830.7200.


In a trial determination, the test item did not solidify as the temperature was decreased from ambient down to -25°C. No further testing was considered necessary. The freezing temperature of the test item, 15-Crown-5, was determined to be less than -25°C.