Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 March 2013 to 21 August 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
25 °C
Vapour pressure:
< 0.004 Pa
Remarks on result:
other: The test item did not change in appearance under the conditions used in the determination.
Conclusions:
The vapor pressure of the test material has been determined to be less than 4.2E-03 Pa at 25°C.
Executive summary:

In an OECD 104 study, conducted according to GLP, the vapour pressure of the test material is less than 0.0042 Pa at 25°C.

Description of key information

In an OECD 104 study, conducted according to GLP, the vapour pressure of the test material is less than 0.0042 Pa at 25°C.

Key value for chemical safety assessment

Vapour pressure:
0.004 Pa
at the temperature of:
25 °C

Additional information