Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-01-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
110
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
33.6

Results of the measurements at a temperature of (20 ± 0.1) °C with a capillary constant of 0.315123 mm²/s²

Test series No.

Mean rundowntime / s

Standard deviation / s

Kinematic viscosity / mm²/s

1

349.4

< 0.1

110.1

2

349.0

< 0.1

110.0

Mean

-

-

110

 

Results of the measurements at a temperature of (40 ± 0.1) °C with a capillary constant of 0.315123 mm²/s²

Test series No.

Mean rundowntime / s

Standard deviation / s

Kinematic viscosity / mm²/s

1

106.4

< 0.1

33.54

2

106.5

< 0.1

33.58

Mean

-

-

33.6

Conclusions:
The kinematic viscosity of the test item was determined to be 110 mm²/s at 20 °C.
Executive summary:

The kinematic viscosity of the test item was determined according to OECD Test Guideline 114, using an ubbelohde viscosimeter. The liquid flowed under gravity through the capillary and the times when the liquid surface reached the start and stop marks were detected. Two test series of 3 measurements, respectively, at temperatures of 20 °C and 40 °C were performed. The kinematic viscosity of the test item was determined to be 110 mm²/s and 33.6 mm²/s at temperatures of (20 ± 0.1) °C and (40 ± 0.1) °C, respectively.

Description of key information

The kinematic viscosity of the test item was determined to be 110 mm²/s at 20 °C.

Key value for chemical safety assessment

Viscosity:
110 mm²/s (static)
at the temperature of:
20 °C

Additional information

The kinematic viscosity of the test item was determined according to OECD Test Guideline 114, using an ubbelohde viscosimeter. The liquid flowed under gravity through the capillary and the times when the liquid surface reached the start and stop marks were detected. Two test series of 3 measurements, respectively, at temperatures of 20 °C and 40 °C were performed. The kinematic viscosity of the test item was determined to be 110 mm²/s and 33.6 mm²/s at temperatures of (20 ± 0.1) °C and (40 ± 0.1) °C, respectively.