Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Version / remarks:
Adopted, 12 May 1981
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Mass median aerodynamic diameter:
3.296 µm
Geometric standard deviation:
0.56
Percentile:
D10
Mean:
0.843 µm
St. dev.:
0.18
Key result
Percentile:
D50
Mean:
3.296 µm
St. dev.:
0.56
Percentile:
D90
Mean:
16.87 µm
St. dev.:
1.5
Conclusions:
The particle size distribution of test item was determined and the testing results were: D10 is 0.843 um, D50 is 3.296 um, D90 is 16.87 um.

Description of key information

The particle size distribution of test item was determined and the testing results were: D10 is 0.843 um, D50 is 3.296 um, D90 is 16.87 um.

Additional information