Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Based on the value of the detection limit(1 × 10-5 hPa) at the highest measurement point (120 °C)the following upper limit vapour pressure values for the test item were calculated:

T / °C

p / hPa

p / Pa

20

< 4.6×10-10

< 4.6×10-8

25

< 8.9×10-10

< 8.9×10-8

50

< 1.8× 10-8

< 1.8× 10-6

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
20 °C

Additional information

Based on the value of the detection limit(1 × 10-5 hPa) at the highest measurement point (120 °C)the following upper limit vapour pressure values for the test item were calculated:

T / °C

p / hPa

p / Pa

20

< 4.6×10-10

< 4.6×10-8

25

< 8.9×10-10

< 8.9×10-8

50

< 1.8× 10-8

< 1.8× 10-6