Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Purity : 96.7% w/w

Results and discussion

Flash point
Key result
Flash point:
172 °C
Atm. press.:
1 030 Bar

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
At room temperature the test item was not flammable; therefore it was heated with a rate of 5°C/min until 200°C.
Four determination were performed on the test item with the Pensky-Martens closer tester.
It can be concluded that the sample produced flammable vapours which can be ignited and the flash point is 172°C (as the mean of the three tests performed). The test article does not meet the criteria to be classified as flammable.