Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14th feb to 11th June 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: - Study generated according to generally valid and/or internationally accepted testing guidelines - Performed according to GLP - Test parameters based on specific testing guideline
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Version / remarks:
92/69/EEC, A2 (Differential Scanning Calorimetry)
Deviations:
no
Principles of method if other than guideline:
EEC Directive 92/69, Part A, Methods for the determination of physico-chemical properties, A.2 “Boiling temperature”, EEC Publication No. L383, December 1992.
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Boiling pt.:
> 400 °C
Atm. press.:
ca. 99.5 kPa

Boiling Point/Boiling Range: A DSC main test run (25°C to 400°C with a heating rate of 10°C/min) confirmed that the test item does not boil under the conditions of the test.

Conclusions:
The aim of this study was to determine the melting and the boiling point/range of FP-100.

Melting Range: The melting range of FP-100 was determined to be from 61.2°C to 107.1°C which is equal to 334.4K to 380.3K.

Boiling Point/Boiling Range: FP-100 did not boil under the conditions of the test (temperature range between 25°C and 400°C).

The atmospheric pressure during the boiling point measurements was 99.5 kPa.
Executive summary:

Not provided

Description of key information

The aim of this study was to determine the boiling point/range of FP-100.
Boiling Point/Boiling Range: FP-100 did not boil under the conditions of the test (temperature range between 25°C and 400°C).
The atmospheric pressure during the boiling point measurements was 99.5 kPa.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
400 °C

Additional information