First-aid measures

Emergency measure - Inhalation: Maybe irritant.

Remove victim to fresh air. Keep victim at rest. Consult a
doctor in event of any complaints.
Emergency measure - Eyes: Mildly irritant.

Wash out with plenty of water with the eyelid held wide open
for at least 15 minutes. Consult a doctor.
Emergency measure - Skin: Not irritant in test, but effects on humans not available.


Remove contaminated clothing. Wash off affected skin with
plenty of water and soap. Consult a doctor in event of any
complaints.
Emergency measure - Ingestion: Information not available.

Wash out mouth with water. Consult a doctor in event of any
complaints.

Fire-fighting measures

Recommended extinguishing agent: A.F.F.F., water spray, CO2, dry chemical

Product arising from burning: CO, CO2

Product determined by test: N

Protective equipment: Self-contained breathing apparatus. Full protective
clothing.

Accidental release measures

Emergency measures in case of spillage: Use appropriate personal protection.

Do not allow to enter sewerage system, natural waters or
soil.

Collect spilled material. Clean affected area with water.

Handling and storage

Handling: Wear suitable protective clothing:

Airlined respirator or dust mask, type P2

Rubber gloves

Safety goggles or face shield

Working clothing, apron and oversleeves.


Ventilation recommended.

Storage: Keep container tightly closed and dry. Store away from
sources of heat.

Packaging of the substance and or preparation: 110L steel drums with two PE innerbags.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Free for transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Totally inert.

Chemical reaction with water: Dissolves very good; no reaction

Dust explosion: Material has a very low bulk density.

Prevent dust explosions.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery: not applicable.

Industry - Possibility of neutralisation: Neutralisation: not applicable.

Industry - Possibility of destruction: controlled discharge: Not applicable.

Industry - Possibility of destruction - incineration: [665] Method of disposal: combustion in an incinerator for
chemical waste.

Industry - Possibility of destruction - water purification: Not applicable.

Industry - Possibility of destruction - other: Not applicable.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.