Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 18 APRIL 2019 to 3 MAY 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Density
Key result
Type:
relative density
Density:
>= 1.231 - <= 1.233 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

1.2323 ± 0.0009 g/cm3 at 20.0 ± 0.2 °C

Applicant's summary and conclusion

Conclusions:
Using the pycnometer method, a density of
1.2323 ± 0.0009 g/cm3 at 20.0 ± 0.2 °C
was measured. This value is the mean of two independent determinations with the maximum error of a single determination.