Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27/05/2015 - 29/05/2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
static method
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
ca. 11.5 Pa

Description of key information

Key value for chemical safety assessment

Vapour pressure:
11.5 Pa
at the temperature of:
20 °C

Additional information