Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
no GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Vapour pressure measurements were taken using a MKS Baratron Capacitance Manometer
GLP compliance:
no
Type of method:
other: using a MKS Baratron Capacitance Manometer

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
21.1 °C
Vapour pressure:
11.7 mm Hg
Vapour pressure at 50°C (if relevant for classification of gas under pressure)
Vapour pressure:
35 mm Hg

Applicant's summary and conclusion

Conclusions:
Vapour pressure measurements were taken using a MKS Baratron Capacitance Manometer (no GLP) on the registered substance itself. The test procedure is in accordance with national standard methods with acceptable restrictions and therefore reliability of Klimisch 2 has been assigned. Vapour pressure: 11.7 mm Hg at 21.1°C and 35 mm Hg at 50°C
Executive summary:

Vapour pressure measurements were taken using a MKS Baratron Capacitance Manometer:

Sample   VP at 10°C (mm Hg)  VP at 21.1°C (mm Hg)  VP at 50°C (mm Hg)  VP at 80°C (mm Hg)
 20190404B  6.4  11.7  35.0  43.7 *