Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling Point)
GLP compliance:
yes (incl. certificate)
Type of method:
method according to Siwoloboff
Decomposition:
yes
Decomp. temp.:
> 300 - < 350 °C
Remarks on result:
not determinable

The sample is a clear liquid in the boiling point tube at room temperature. During the course of heating, sample decomposition was observed. Decomposition was indicated by a drastic change in the sample color from clear to black. The sample did not boil.

Conclusions:
The boiling point of the test material could not be determined due to sample decomposition.
Executive summary:

The boiling point of the test material could not be determined due to sample decomposition.

Description of key information

The test material is a clear liquid in the boiling point tube at room temperature. During the course of heating, sample decomposition was observed below 350 C. Decomposition was indicated by a drastic change in the sample color from clear to black. The sample did not boil.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
350 °C

Additional information