Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted according to an internationally recognised method, with no deviation, but non-GLP. The substance is considered to be adequately characterised. Therefore validation applies with restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Council Regulation (EC) No 440/2008
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of methyl (3E)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate and methyl (3Z)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate
EC Number:
951-493-2
Molecular formula:
C17H28O2
IUPAC Name:
Reaction mass of methyl (3E)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate and methyl (3Z)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate
Test material form:
liquid
Details on test material:
Appearance: orange liquid

Results and discussion

Flash point
Flash point:
> 150 °C
Atm. press.:
975 hPa

Any other information on results incl. tables

Accuracy: ± 2 °C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The Flash Point of the test substance was measured according to EU A9 guideline, closed cup method.
Experiment was performed in duplicate.
Flash point was measured as >150°C at 975 hPa.
Executive summary:

The Flash Point of the test substance was measured according to EU A9 guideline, closed cup method.

Experiment was performed in duplicate.

Flash point was measured as >150°C at 975 hPa.