Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
see Commission Regulation (EC) No 440/2008 of 30 May 2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (OJ L 142, 31.5.2008, p. 1) A.9, 1.6.3
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
142.5 °C
Atm. press.:
100.5 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point is 142.5 °C (corrected) at 101.3 kPa.
Executive summary:

The flash point of the test item "sandalwood oil" has been tested according to the test method ASTM D93.

The flash point is 142.5 °C at 101.3 kPa.

Description of key information

The flash point of the test item "pure Australian sandalwood oil" has been tested according to the test method ASTM D93.

The flash point is 142.5 °C according to the key study at 101.3 kPa. This value is above the GHS threshold for classification.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
142.5 °C

Additional information