Registration Dossier

Diss Factsheets

Some information in this page has been claimed confidential.

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous

Results and discussion

Viscosity
Key result
Temp.:
other: 25 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 50

Applicant's summary and conclusion