Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 217-044-3 | CAS number: 1729-67-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 2019-02-14 to 2019-10-22
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Study performed to EU Method with no significant deviations and run in OECD GLP certified lab.
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester.
- Version / remarks:
- 2012
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- closed cup
- Flash point apparatus:
- other: Eraflash flash-point tester
- Specific details on test material used for the study:
- Batch No.: 800327680
Purity: 98% - Key result
- Remarks on result:
- no flash point according to standard method
- Conclusions:
- No ignition of the test item was observed. According to this, the test item has no flash-point.
- Executive summary:
The flash point of test item was determined according to ASTM D7094.
An attempt was made to determine the flash-point of the test item using an Eraflash flash-point tester (Eralytics, Vienna, Austria). The flash-point could not be determined using non-equilibrium and equilibrium method due to constant error given by the Eraflash tester.
Therefore an attempt was made to ignite the test item using a flame of a gas burner. A test cup was filled with approximately 2.3 g of test item. A flame of a gas burner was applied to the vessel for 20 seconds and it was visually observed if the test item ignited.
In contact with the flame of the gas burner the test item did not ignite. Black smoke was observed. According to this, the test item does not have a flash-point.
Reference
In contact with the flame of the gas burner the test item did not ignite. Black smoke was observed. According to this, the test item does not have a flash-point.
Description of key information
The flash point of test item was determined according to ASTM D7094.
The flash-point could not be determined using non-equilibrium and equilibrium method due to constant error given by the Eraflash tester. Therefore an attempt was made to ignite the test item using a flame of a gas burner.
In contact with the flame of the gas burner the test item did not ignite. Black smoke was observed. According to this, the test item does not have a flash-point.
Key value for chemical safety assessment
Additional information
In contact with the flame of the gas burner the test item did not ignite. Black smoke was observed. According to this, the test item does not have a flash-point.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.