Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11th September 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
Principles of method if other than guideline:
Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
other: Calculation of Kinematic Viscosity
Standard covering the apparatus used:
Anton Paar SVM Stabinger Viscosimeter
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: lot 05347/MA
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
874
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
261
Executive summary:

The kinematic viscosity was measured as 874 mm²/s at 20 °C and 261 mm²/s at 40 °C.

Description of key information

Key value for chemical safety assessment

Viscosity:
874 mm²/s (static)
at the temperature of:
20 °C

Additional information

261 mm²/s at 40 °C