Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11th September 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
Principles of method if other than guideline:
Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
other: Calculation of Kinematic Viscosity
Standard covering the apparatus used:
Anton Paar SVM Stabinger Viscosimeter
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: lot 05347/MA
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
874
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
261
Executive summary:

The kinematic viscosity was measured as 874 mm²/s at 20 °C and 261 mm²/s at 40 °C.

Description of key information

Key value for chemical safety assessment

Viscosity:
874 mm²/s (static)
at the temperature of:
20 °C

Additional information

261 mm²/s at 40 °C