Registration Dossier

Administrative data

Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26Nov2001 to 11Dec2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[(4-aminophenyl)azo]-1,3-dimethyl-1H-imidazolium chloride
EC Number:
306-764-4
EC Name:
2-[(4-aminophenyl)azo]-1,3-dimethyl-1H-imidazolium chloride
Cas Number:
97404-02-9
Molecular formula:
C11H14N5.Cl
IUPAC Name:
2-[(4-aminophenyl)azo]-1,3-dimethyl-1H-imidazolium chloride
Test material form:
solid: particulate/powder
Details on test material:
See individual study reports for purity information and CofA where applicable

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
no explosion observed with either 6mm or 2mm orifice plate
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
It was found that Fthe test item, is not an explosive Item according to the EC Directive 92/69/EEC, A.14.
Executive summary:

Testing was undertaken using methods described in EC Directive 92/69/EEC, A.14 for thermal, mechanical shock and mechanical friction sensitivity.

It was found that the test item is not an explosive Item according to the EC Directive 92/69/EEC, A.14