Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid non flammable in air, e.g. no flash point up to 200°C
Justification for type of information:
JUSTIFICATION FOR DATA WAIVINGBased on high Flash Point (137°C), and lack of exothermal reaction up to boiling point (>250°C), no particular hazard is anticipated in normal conditions of storage, handling and use.Moreover, the Auto-Ignition Temperature is not a criteria for CLP classification.Therefore, the experimental study was deemed unnecessary.