Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
other:
Type of information:
experimental study
Adequacy of study:
supporting study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
pyrophoric liquids
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
Test procedure:
ignition time on contact with air
Result:
3 min
Test procedure:
effect on filter paper
Result:
> 1 - < 2 min
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
Qualifier:
according to guideline
Guideline:
other:
Type of method:
closed cup
Flash point:
> 100 °C
Remarks on result:
no flash point up to 100°C
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other:
Type of method:
open cup
Flash point:
51.7 °C

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
69 °C
Remarks on result:
other:

Applicant's summary and conclusion