Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-01-31 to 2017-06-06
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.6: “Non-Viscous Flammable Liquids”
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester

Test material

Constituent 1
Chemical structure
Reference substance name:
(-)-[R-(R*,R*)]-6-fluoro-3,4-dihydro-2-(2-oxiranyl)-2H-1-benzopyran
EC Number:
606-373-1
Cas Number:
197706-50-6
Molecular formula:
C11H11FO2
IUPAC Name:
(-)-[R-(R*,R*)]-6-fluoro-3,4-dihydro-2-(2-oxiranyl)-2H-1-benzopyran
Test material form:
liquid: viscous
Details on test material:
- Physical state: Viscous liquid
- Appearance: Yellow to orange, clear liquid
Specific details on test material used for the study:
- Batch n°: I16HB3200
- Analytical purity: 83.7%
- Expiration date: 2017-07-25
- Storage condition: at room temperature

Results and discussion

Flash point
Flash point:
80 °C
Atm. press.:
101.325 kPa

Any other information on results incl. tables

Preliminary test

The estimated flash-point of the test item was 77°C.

Main test

The results of the main study are shown below.

Test

Flash-point

[°C]

Lowest flash-point

[°C]

 

 

 

1

80

80

2

80

 

 

 

 

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of JNJ-17337008-AAA (T001591).

The flash-point of the test item was 80°C.