Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-01-31 to 2017-06-06
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.6: “Non-Viscous Flammable Liquids”
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester

Test material

Constituent 1
Chemical structure
Reference substance name:
(-)-[R-(R*,R*)]-6-fluoro-3,4-dihydro-2-(2-oxiranyl)-2H-1-benzopyran
EC Number:
606-373-1
Cas Number:
197706-50-6
Molecular formula:
C11H11FO2
IUPAC Name:
(-)-[R-(R*,R*)]-6-fluoro-3,4-dihydro-2-(2-oxiranyl)-2H-1-benzopyran
Test material form:
liquid: viscous
Details on test material:
- Physical state: Viscous liquid
- Appearance: Yellow to orange, clear liquid
Specific details on test material used for the study:
- Batch n°: I16HB3200
- Analytical purity: 83.7%
- Expiration date: 2017-07-25
- Storage condition: at room temperature

Results and discussion

Flash point
Flash point:
80 °C
Atm. press.:
101.325 kPa

Any other information on results incl. tables

Preliminary test

The estimated flash-point of the test item was 77°C.

Main test

The results of the main study are shown below.

Test

Flash-point

[°C]

Lowest flash-point

[°C]

 

 

 

1

80

80

2

80

 

 

 

 

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of JNJ-17337008-AAA (T001591).

The flash-point of the test item was 80°C.