Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
other: Innospec SOP TM015 Revision: 3 “Flashpoint”
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
99.3 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Executive summary:

The flashpoint of the Test Item was determined to be 99.3°C

Description of key information

The flashpoint of the Test Item was determined to be 99.30°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
99.3 °C

Additional information